Abstract

Background: Hypertrophic scarring may be a cause of failure after transcanalicular laser dacryocystorhinostomy (DCR) surgery. This hypertrophic scarring results from tissue charring and excessive coagulation, which may be caused by the high laser energy. We have evaluated the use of low energy settings to prevent hypertrophic scarring, for a successful outcome. Aims: To perform and evaluate transcanalicular laser DCR using low energy 810 nm diode laser. Design: Interventional, non-comparative, case series. Materials and methods: Patients with nasolacrimal duct obstruction and chronic dacryocystitis, who needed DCR, and were fit for surgery under local anesthesia, were recruited to undergo transcanalicular laser DCR using a 810 nm diode laser. The outcome was measured by the patency of the lacrimal passage, as indicated by the relief in the symptoms and the patency on syringing at the last follow-up. The surgical time and surgical complications were noted. Statistical analysis used: Descriptive analysis. Results: The study included 94 patients. The average age was 30.1 years (range 15 - 69 years). Seventy (74.4%) patients were female. Eight patients had failed external DCR. Per-operative patency of the passage was obtained in all the patients. Average surgical time was seven minutes (5 - 18 minutes). At the end of the study period of one year, a successful outcome was seen in 85 patients (90.5%). There were eight patients of previous failed DCR surgeries, and six of them achieved a cure at the end of follow-up. Conclusions: Transcanalicular Laser DCR can be safely performed using a low power 810 nm diode laser. The surgery is elegant, minimally invasive, allows fast rehabilitation, and has an excellent success rate.

Keywords

Subject

Publication details

DOI
10.4103/0974-620x.106101
Journal
Oman Journal of Ophthalmology, 5(3), 171-174
Publisher
Medknow Publications
Open access
Gold open access

Cite this article

APA 7

Gupta, S. K., Kumar, A., Agarwal, S., & Pandey, P. (2012). Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser. Oman Journal of Ophthalmology, 5(3), 171-174. https://doi.org/10.4103/0974-620x.106101

MLA 9

Gupta, Sanjiv K, et al. "Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser." Oman Journal of Ophthalmology, vol. 5, no. 3, 2012, pp. 171-174. https://doi.org/10.4103/0974-620x.106101.

Chicago (author–date)

Gupta, Sanjiv K, Ajai Kumar, Swati Agarwal, and Paritosh Pandey. 2012. "Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser." Oman Journal of Ophthalmology 5 (3): 171-174. https://doi.org/10.4103/0974-620x.106101.

Harvard

Gupta, S. K., Kumar, A., Agarwal, S. and Pandey, P. (2012) 'Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser', Oman Journal of Ophthalmology, 5(3), pp. 171-174. doi:10.4103/0974-620x.106101.

Vancouver

Gupta SK, Kumar A, Agarwal S, Pandey P. Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser. Oman Journal of Ophthalmology. 2012;5(3):171-174. doi:10.4103/0974-620x.106101

IEEE

S. K. Gupta, A. Kumar, S. Agarwal, and P. Pandey, "Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser," Oman Journal of Ophthalmology, vol. 5, no. 3, pp. 171-174, 2012, doi: 10.4103/0974-620x.106101.