الملخص
Background: Hypertrophic scarring may be a cause of failure after transcanalicular laser dacryocystorhinostomy (DCR) surgery. This hypertrophic scarring results from tissue charring and excessive coagulation, which may be caused by the high laser energy. We have evaluated the use of low energy settings to prevent hypertrophic scarring, for a successful outcome. Aims: To perform and evaluate transcanalicular laser DCR using low energy 810 nm diode laser. Design: Interventional, non-comparative, case series. Materials and methods: Patients with nasolacrimal duct obstruction and chronic dacryocystitis, who needed DCR, and were fit for surgery under local anesthesia, were recruited to undergo transcanalicular laser DCR using a 810 nm diode laser. The outcome was measured by the patency of the lacrimal passage, as indicated by the relief in the symptoms and the patency on syringing at the last follow-up. The surgical time and surgical complications were noted. Statistical analysis used: Descriptive analysis. Results: The study included 94 patients. The average age was 30.1 years (range 15 - 69 years). Seventy (74.4%) patients were female. Eight patients had failed external DCR. Per-operative patency of the passage was obtained in all the patients. Average surgical time was seven minutes (5 - 18 minutes). At the end of the study period of one year, a successful outcome was seen in 85 patients (90.5%). There were eight patients of previous failed DCR surgeries, and six of them achieved a cure at the end of follow-up. Conclusions: Transcanalicular Laser DCR can be safely performed using a low power 810 nm diode laser. The surgery is elegant, minimally invasive, allows fast rehabilitation, and has an excellent success rate.
الكلمات المفتاحية
بيانات النشر
- المعرّف الرقمي
- 10.4103/0974-620x.106101
- المجلة
- المجلة العُمانية لطب العيون, 5(3), 171-174
- الناشر
- منشورات ميدنو
- وصول مفتوح
- وصول مفتوح ذهبي
اقتبس هذه المقالة
APA 7
Gupta, S. K., Kumar, A., Agarwal, S., & Pandey, P. (2012). Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser. Oman Journal of Ophthalmology, 5(3), 171-174. https://doi.org/10.4103/0974-620x.106101
MLA 9
Gupta, Sanjiv K, et al. "Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser." Oman Journal of Ophthalmology, vol. 5, no. 3, 2012, pp. 171-174. https://doi.org/10.4103/0974-620x.106101.
شيكاغو (المؤلف–التاريخ)
Gupta, Sanjiv K, Ajai Kumar, Swati Agarwal, and Paritosh Pandey. 2012. "Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser." Oman Journal of Ophthalmology 5 (3): 171-174. https://doi.org/10.4103/0974-620x.106101.
هارفارد
Gupta, S. K., Kumar, A., Agarwal, S. and Pandey, P. (2012) 'Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser', Oman Journal of Ophthalmology, 5(3), pp. 171-174. doi:10.4103/0974-620x.106101.
فانكوفر
Gupta SK, Kumar A, Agarwal S, Pandey P. Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser. Oman Journal of Ophthalmology. 2012;5(3):171-174. doi:10.4103/0974-620x.106101