Abstract
Purpose: The purpose of this study was to evaluate the amount of sensitivity and specificity of the slit-light (SL) method in the diagnosis of ocular cyclotorsion. Materials and methods: One hundred and twenty eyes of 60 individuals (10-60 years old), with mean visual acuity of 0.08 ± 0.14 LogMAR, were divided into two groups (normal and torsion groups). Individuals without ocular motility disorder were selected as normal and patients with extraocular motility disorders and oblique muscle dysfunctions as the torsion group. The sensitivity and specificity of SL in the diagnosis of ocular torsion were measured by masked investigators and compared to fundus photography (FP). Inter- and intraobserver variability of these techniques was also determined. Results: The amounts of sensitivity and specificity of SL, measured by the first examiner, were 60% and 92% for intorsion and 50% and 96% for extorsion assessment, respectively. These amounts were 53% and 95% for intorsion, and 54% and 97% for extorsion by the second examiner. The contingency coefficient between the two examiners was 68.6% for SL. This amount was 61% between FP and SL for the first examiner and 63% for the second. The contingency coefficient for the repeatability of SL was 72.2% for the first examiner and 75.7% for the second. This amount was 71.2% between the two examiners. Conclusion: SL can be considered a useful method for the diagnosis of cyclotorsion.
Keywords
Publication details
- DOI
- 10.4103/ojo.ojo_82_23
- Journal
- Oman Journal of Ophthalmology, 17(2), 245-248
- Publisher
- Medknow Publications
- Open access
- Gold open access
Cite this article
APA 7
Sabermoghadam, A., Sharifi, M., & Shakeri, M. T. (2024). Evaluation of sensitivity and specificity of the slit-light method in the diagnosis of cyclotorsion. Oman Journal of Ophthalmology, 17(2), 245-248. https://doi.org/10.4103/ojo.ojo_82_23
MLA 9
Sabermoghadam, Aliakbar, et al. "Evaluation of sensitivity and specificity of the slit-light method in the diagnosis of cyclotorsion." Oman Journal of Ophthalmology, vol. 17, no. 2, 2024, pp. 245-248. https://doi.org/10.4103/ojo.ojo_82_23.
Chicago (author–date)
Sabermoghadam, Aliakbar, Mohammad Sharifi, and Mohammad Taghi Shakeri. 2024. "Evaluation of sensitivity and specificity of the slit-light method in the diagnosis of cyclotorsion." Oman Journal of Ophthalmology 17 (2): 245-248. https://doi.org/10.4103/ojo.ojo_82_23.
Harvard
Sabermoghadam, A., Sharifi, M. and Shakeri, M. T. (2024) 'Evaluation of sensitivity and specificity of the slit-light method in the diagnosis of cyclotorsion', Oman Journal of Ophthalmology, 17(2), pp. 245-248. doi:10.4103/ojo.ojo_82_23.
Vancouver
Sabermoghadam A, Sharifi M, Shakeri MT. Evaluation of sensitivity and specificity of the slit-light method in the diagnosis of cyclotorsion. Oman Journal of Ophthalmology. 2024;17(2):245-248. doi:10.4103/ojo.ojo_82_23
IEEE
A. Sabermoghadam, M. Sharifi, and M. T. Shakeri, "Evaluation of sensitivity and specificity of the slit-light method in the diagnosis of cyclotorsion," Oman Journal of Ophthalmology, vol. 17, no. 2, pp. 245-248, 2024, doi: 10.4103/ojo.ojo_82_23.