الملخص

Objectives: This study aimed to evaluate real-world glycaemic outcomes associated with flash glucose monitoring (FGM) use in patients with diabetes at Sultan Qaboos University Hospital, Muscat, Oman. Methods: This retrospective cross-sectional study was conducted among diabetic patients using flash glucose monitoring between January 2022 and August 2023. Patients were grouped by scanning frequency, time-in-range (TIR) and estimated A1c (eA1c). Associations between scanning frequency and glycaemic metrics were analysed. Results: A total of 436 patients were included in this study. Patients with higher scanning frequency (≥12 scans/day, median = 17) achieved greater TIR (52.4% versus 34.8%), lower time-above-range (41.8% versus 57.0%), lower eA1c (7.7% versus 9.0%) and lower glucose standard deviation (70.22 mg/dL versus 82.21 mg/dL) compared with those with the lowest scanning frequency (≤3 scans/day). No significant association was found between scanning frequency and time-below-range or glucose coefficient of variation. Conclusion: Frequent FGM scanning was associated with improved glycaemic control in Omani diabetes patients, supporting its role in real-world diabetes management.

بيانات النشر

المعرّف الرقمي
10.18295/2075-0528.2952
المجلة
مجلة جامعة السلطان قابوس الطبية, 26(1), 29-35
الناشر
جامعة السلطان قابوس
وصول مفتوح
وصول مفتوح ذهبي
الترخيص
CC BY-ND 4.0

اقتبس هذه المقالة

APA 7

Al-Mamari, A., Al Gharabi, S., Al Busaidy, M., & Al Futaisi, A. (2026). Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study. Sultan Qaboos University Medical Journal, 26(1), 29-35. https://doi.org/10.18295/2075-0528.2952

MLA 9

Al-Mamari, Ammar, et al. "Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study." Sultan Qaboos University Medical Journal, vol. 26, no. 1, 2026, pp. 29-35. https://doi.org/10.18295/2075-0528.2952.

شيكاغو (المؤلف–التاريخ)

Al-Mamari, Ammar, Sumaia Al Gharabi, Merah Al Busaidy, and Abdulla Al Futaisi. 2026. "Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study." Sultan Qaboos University Medical Journal 26 (1): 29-35. https://doi.org/10.18295/2075-0528.2952.

هارفارد

Al-Mamari, A., Al Gharabi, S., Al Busaidy, M. and Al Futaisi, A. (2026) 'Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study', Sultan Qaboos University Medical Journal, 26(1), pp. 29-35. doi:10.18295/2075-0528.2952.

فانكوفر

Al-Mamari A, Al Gharabi S, Al Busaidy M, Al Futaisi A. Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study. Sultan Qaboos University Medical Journal. 2026;26(1):29-35. doi:10.18295/2075-0528.2952

IEEE

A. Al-Mamari, S. Al Gharabi, M. Al Busaidy, and A. Al Futaisi, "Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study," Sultan Qaboos University Medical Journal, vol. 26, no. 1, pp. 29-35, 2026, doi: 10.18295/2075-0528.2952.