        "id": "osp-9845",
        "type": "article-journal",
        "title": "Real-World Data Investigating the Frequency of Flash Glucose Monitoring and Glycaemic Metrics in Omani Diabetes Patients: A preliminary retrospective cross-sectional study",
        "author": [
            {
                "family": "Al-Mamari",
                "given": "Ammar"
            },
            {
                "family": "Al Gharabi",
                "given": "Sumaia"
            },
            {
                "family": "Al Busaidy",
                "given": "Merah"
            },
            {
                "family": "Al Futaisi",
                "given": "Abdulla"
            }
        ],
        "URL": "https://omanscience.com/ar/articles/real-world-data-investigating-the-frequency-of-flash-glucose-monitoring-and-glycaemic-metrics-in-omani-diabetes-patients-a-preliminary-retrospective-c",
        "language": "en",
        "issued": {
            "date-parts": [
                [
                    2026
                ]
            ]
        },
        "container-title": "Sultan Qaboos University Medical Journal",
        "volume": "26",
        "issue": "1",
        "page": "29-35",
        "DOI": "10.18295/2075-0528.2952",
        "publisher": "Sultan Qaboos University",
        "ISSN": "2075-051X",
        "abstract": "Objectives: This study aimed to evaluate real-world glycaemic outcomes associated with flash glucose monitoring (FGM) use in patients with diabetes at Sultan Qaboos University Hospital, Muscat, Oman. Methods: This retrospective cross-sectional study was conducted among diabetic patients using flash glucose monitoring between January 2022 and August 2023. Patients were grouped by scanning frequency, time-in-range (TIR) and estimated A1c (eA1c). Associations between scanning frequency and glycaemic metrics were analysed. Results: A total of 436 patients were included in this study. Patients with higher scanning frequency (≥12 scans/day, median = 17) achieved greater TIR (52.4% versus 34.8%), lower time-above-range (41.8% versus 57.0%), lower eA1c (7.7% versus 9.0%) and lower glucose standard deviation (70.22 mg/dL versus 82.21 mg/dL) compared with those with the lowest scanning frequency (≤3 scans/day). No significant association was found between scanning frequency and time-below-range or glucose coefficient of variation. Conclusion: Frequent FGM scanning was associated with improved glycaemic control in Omani diabetes patients, supporting its role in real-world diabetes management."
    }
]