Abstract

With the advent of nonpenetrating glaucoma surgeries (NPGS), these techniques are noticed more considerably by glaucoma surgeons due to lower complications in comparison to penetrating surgeries with comparable outcomes. One of the main objectives in these surgeries is the creation of an intrascleral filtering space as an alternative for subconjunctival filtering bleb. Intrascleral fibrosis in the long term reduces the volume of intrascleral bleb, so the use of implants as a space holder for preventing the collapse of scleral flaps and continued aqueous humor drainage is recommended. A lot of materials with diverse designs have been used as implants in NPGS. In this study, the remaining of Ahmed valve's tube was used as an implant in four eyes of four patients. The technique for the implant we introduced, offers significant advantages over previously reported implants. The material is biocompatible, low cost, and easily accessible in all the centers performing glaucoma surgeries.

Keywords

Publication details

DOI
10.4103/ojo.ojo_11_2019
Journal
Oman Journal of Ophthalmology, 13(1), 40-42
Publisher
Medknow Publications
Open access
Gold open access

Cite this article

APA 7

Shokoohi-Rad, S., Kiarudi, M. Y., & Ansari-Astaneh, M. R. (2020). Innovative usage of the remaining portion of Ahmed glaucoma valve tube as an implant in nonpenetrating glaucoma surgery. Oman Journal of Ophthalmology, 13(1), 40-42. https://doi.org/10.4103/ojo.ojo_11_2019

MLA 9

Shokoohi-Rad, Saeed, et al. "Innovative usage of the remaining portion of Ahmed glaucoma valve tube as an implant in nonpenetrating glaucoma surgery." Oman Journal of Ophthalmology, vol. 13, no. 1, 2020, pp. 40-42. https://doi.org/10.4103/ojo.ojo_11_2019.

Chicago (author–date)

Shokoohi-Rad, Saeed, Mohammad Yaser Kiarudi, and Mohammad-Reza Ansari-Astaneh. 2020. "Innovative usage of the remaining portion of Ahmed glaucoma valve tube as an implant in nonpenetrating glaucoma surgery." Oman Journal of Ophthalmology 13 (1): 40-42. https://doi.org/10.4103/ojo.ojo_11_2019.

Harvard

Shokoohi-Rad, S., Kiarudi, M. Y. and Ansari-Astaneh, M. R. (2020) 'Innovative usage of the remaining portion of Ahmed glaucoma valve tube as an implant in nonpenetrating glaucoma surgery', Oman Journal of Ophthalmology, 13(1), pp. 40-42. doi:10.4103/ojo.ojo_11_2019.

Vancouver

Shokoohi-Rad S, Kiarudi MY, Ansari-Astaneh MR. Innovative usage of the remaining portion of Ahmed glaucoma valve tube as an implant in nonpenetrating glaucoma surgery. Oman Journal of Ophthalmology. 2020;13(1):40-42. doi:10.4103/ojo.ojo_11_2019

IEEE

S. Shokoohi-Rad, M. Y. Kiarudi, and M. R. Ansari-Astaneh, "Innovative usage of the remaining portion of Ahmed glaucoma valve tube as an implant in nonpenetrating glaucoma surgery," Oman Journal of Ophthalmology, vol. 13, no. 1, pp. 40-42, 2020, doi: 10.4103/ojo.ojo_11_2019.