Abstract

Context: Intraocular lenses with variable total diameter are supposed to fit better in the capsular bag and lead to fewer complications. Aims: This study aims to investigate the efficacy and the safety of an intraocular lens model with variable total diameter. Settings and design: Prospective randomized intraindividual study. Subjects and methods: Thirty-two eyes of sixteen patients with bilateral age-related cataract received standard cataract surgery with implantation of an intraocular lens with a standard diameter in one eye (Quatrix®, Group A) and with a variable total diameter in the fellow eye (Quatrix Evolutive®, Group B). Primary study endpoints included evaluation of refraction stability and posterior capsule opacification (PCO) over a follow-up period of 6 months. Statistical analysis used: SPSS (Version 19.0) was used for statistical analysis. Results: Uncorrected and corrected distant visual acuity after 6 months were 0.24 and 0.1 LogMAR in Group A and 0.23 and 0.09 LogMAR in Group B, respectively. The objective and manifest spherical equivalent (OSE, MSE) 6 months postoperatively were + 0.65 D and + 0.62 D in Group A compared to + 0.33 D and + 0.33 D in Group B respectively (P = 0.665 for OSE, P = 0.208 for MSE). PCO-index increased statistically significant in both groups (P = 0.004 in Group A, P = 0.046 in Group B), but the difference of PCO-index between both groups was not statistically significant (P = 0.569). Conclusions: An intraocular lens with a variable total diameter shows good visual outcomes and safety performance as well as same outcomes concerning postoperative refractive stability and development of PCO compared to an intraocular lens with standard total diameter.

Keywords

Publication details

DOI
10.4103/ojo.ojo_143_2017
Journal
Oman Journal of Ophthalmology, 11(2), 144-149
Publisher
Medknow Publications
Open access
Gold open access

Cite this article

APA 7

Vounotrypidis, E., Lackerbauer, C., Kook, D., Dirisamer, M., Priglinger, S., & Mayer, W. J. (2018). Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery. Oman Journal of Ophthalmology, 11(2), 144-149. https://doi.org/10.4103/ojo.ojo_143_2017

MLA 9

Vounotrypidis, Efstathios, et al. "Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery." Oman Journal of Ophthalmology, vol. 11, no. 2, 2018, pp. 144-149. https://doi.org/10.4103/ojo.ojo_143_2017.

Chicago (author–date)

Vounotrypidis, Efstathios, Carlo Lackerbauer, Daniel Kook, Martin Dirisamer, Siegfried Priglinger, and Wolfgang J Mayer. 2018. "Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery." Oman Journal of Ophthalmology 11 (2): 144-149. https://doi.org/10.4103/ojo.ojo_143_2017.

Harvard

Vounotrypidis, E., Lackerbauer, C., Kook, D., Dirisamer, M., Priglinger, S. and Mayer, W. J. (2018) 'Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery', Oman Journal of Ophthalmology, 11(2), pp. 144-149. doi:10.4103/ojo.ojo_143_2017.

Vancouver

Vounotrypidis E, Lackerbauer C, Kook D, Dirisamer M, Priglinger S, Mayer WJ. Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery. Oman Journal of Ophthalmology. 2018;11(2):144-149. doi:10.4103/ojo.ojo_143_2017

IEEE

E. Vounotrypidis, C. Lackerbauer, D. Kook, M. Dirisamer, S. Priglinger, and W. J. Mayer, "Influence of total intraocular lens diameter on efficacy and safety for in the bag cataract surgery," Oman Journal of Ophthalmology, vol. 11, no. 2, pp. 144-149, 2018, doi: 10.4103/ojo.ojo_143_2017.