Abstract

Background: The background of the study was to design and validate an Arabic logMAR (UOB) version chart for testing distance visual acuity based on the constructed principle conceived by Bailey and Lovie chart. Methods: Selected Arabic alphabets were designed on a 5 × 5 grid to test the visual acuity at 4 m distance. Out of the 28 Arabic alphabets, 10 optotypes with comparable legibility elements were chosen experimentally to construct the chart. The validity and repeatability were examined of the designed against a standard logMAR chart and existing Arabic logMAR (Al Mufarrej) version using the paired t-test. Results: A total of 14 rows (1.0 to-0.3 logMAR) with five letters in each line were designed with the range of legibility between 1.07913 and 0.993822. The visual acuity score of UOB Arabic logMAR ranged between -0.02 and 0.24 (mean 0.045 ± 0.061. The chart demonstrated no significant difference compared with the standard logMAR (P = 0.248) and Al Mufarrej logMAR version (P = 0.318). Conclusion: The newly constructed Arabic logMAR UOB version chart has demonstrated good validity and repeatability when compared to the standard logMAR. The statistical differences in visual acuity measurements between the newly Arabic logMAR UOB version chart, and the standard logMAR chart was within the acceptable limits. Likewise, it can be registered, listed, and used to test visual acuity clinically among the literate Arabic population.

Keywords

Publication details

DOI
10.4103/ojo.ojo_67_24
Journal
Oman Journal of Ophthalmology, 18(3), 291-295
Publisher
Medknow Publications
Open access
Gold open access

Cite this article

APA 7

Ismail, G. M., Mohamed, Z., Noushad, B., Kandil, A., & Al-Shahi, B. A. (2025). Design and validation of the Arabic LogMAR chart, University of Buraimi (UoB) version. Oman Journal of Ophthalmology, 18(3), 291-295. https://doi.org/10.4103/ojo.ojo_67_24

MLA 9

Ismail, Galal Mohamed, et al. "Design and validation of the Arabic LogMAR chart, University of Buraimi (UoB) version." Oman Journal of Ophthalmology, vol. 18, no. 3, 2025, pp. 291-295. https://doi.org/10.4103/ojo.ojo_67_24.

Chicago (author–date)

Ismail, Galal Mohamed, Zoelfigar Mohamed, Babu Noushad, Ahmed Kandil, and Badour Ali Al-Shahi. 2025. "Design and validation of the Arabic LogMAR chart, University of Buraimi (UoB) version." Oman Journal of Ophthalmology 18 (3): 291-295. https://doi.org/10.4103/ojo.ojo_67_24.

Harvard

Ismail, G. M., Mohamed, Z., Noushad, B., Kandil, A. and Al-Shahi, B. A. (2025) 'Design and validation of the Arabic LogMAR chart, University of Buraimi (UoB) version', Oman Journal of Ophthalmology, 18(3), pp. 291-295. doi:10.4103/ojo.ojo_67_24.

Vancouver

Ismail GM, Mohamed Z, Noushad B, Kandil A, Al-Shahi BA. Design and validation of the Arabic LogMAR chart, University of Buraimi (UoB) version. Oman Journal of Ophthalmology. 2025;18(3):291-295. doi:10.4103/ojo.ojo_67_24

IEEE

G. M. Ismail, Z. Mohamed, B. Noushad, A. Kandil, and B. A. Al-Shahi, "Design and validation of the Arabic LogMAR chart, University of Buraimi (UoB) version," Oman Journal of Ophthalmology, vol. 18, no. 3, pp. 291-295, 2025, doi: 10.4103/ojo.ojo_67_24.