Abstract

To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany) revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

Keywords

Publication details

DOI
10.4103/0974-620x.209109
Journal
Oman Journal of Ophthalmology, 10(2), 106-108
Publisher
Medknow Publications
Open access
Gold open access

Cite this article

APA 7

Tabatabaei, S. A., Soleimani, M., & Johari, M. (2017). Corneal ring infiltration in contact lens wearers. Oman Journal of Ophthalmology, 10(2), 106-108. https://doi.org/10.4103/0974-620x.209109

MLA 9

Tabatabaei, Seyed Ali, et al. "Corneal ring infiltration in contact lens wearers." Oman Journal of Ophthalmology, vol. 10, no. 2, 2017, pp. 106-108. https://doi.org/10.4103/0974-620x.209109.

Chicago (author–date)

Tabatabaei, Seyed Ali, Mohammad Soleimani, and Mohammadkarim Johari. 2017. "Corneal ring infiltration in contact lens wearers." Oman Journal of Ophthalmology 10 (2): 106-108. https://doi.org/10.4103/0974-620x.209109.

Harvard

Tabatabaei, S. A., Soleimani, M. and Johari, M. (2017) 'Corneal ring infiltration in contact lens wearers', Oman Journal of Ophthalmology, 10(2), pp. 106-108. doi:10.4103/0974-620x.209109.

Vancouver

Tabatabaei SA, Soleimani M, Johari M. Corneal ring infiltration in contact lens wearers. Oman Journal of Ophthalmology. 2017;10(2):106-108. doi:10.4103/0974-620x.209109

IEEE

S. A. Tabatabaei, M. Soleimani, and M. Johari, "Corneal ring infiltration in contact lens wearers," Oman Journal of Ophthalmology, vol. 10, no. 2, pp. 106-108, 2017, doi: 10.4103/0974-620x.209109.