[
    {
        "id": "osp-12696",
        "type": "article-journal",
        "title": "Clinical utility of anterior segment swept-source optical coherence tomography in glaucoma",
        "author": [
            {
                "family": "Angmo",
                "given": "Dewang"
            },
            {
                "family": "Nongpiur",
                "given": "Monisha E"
            },
            {
                "family": "Sharma",
                "given": "Reetika"
            },
            {
                "family": "Sidhu",
                "given": "Talvir"
            },
            {
                "family": "Sihota",
                "given": "Ramanjit"
            },
            {
                "family": "Dada",
                "given": "Tanuj"
            }
        ],
        "URL": "https://omanscience.com/en/articles/clinical-utility-of-anterior-segment-swept-source-optical-coherence-tomography-in-glaucoma",
        "language": "en",
        "issued": {
            "date-parts": [
                [
                    2016
                ]
            ]
        },
        "container-title": "Oman Journal of Ophthalmology",
        "volume": "9",
        "issue": "1",
        "page": "3-10",
        "DOI": "10.4103/0974-620x.176093",
        "publisher": "Medknow Publications",
        "ISSN": "0974-620X",
        "abstract": "Unlabelled: Optical coherence tomography (OCT), a noninvasive imaging modality that uses low-coherence light to obtain a high-resolution cross-section of biological structures, has evolved dramatically over the years. The Swept-source OCT (SS-OCT) makes use of a single detector with a rapidly tunable laser as a light source. The Casia SS-1000 OCT is a Fourier-domain, SS-OCT designed specifically for imaging the anterior segment. This system achieves high resolution imaging of 10΅m (Axial) and 30΅m (Transverse) and high speed scanning of 30,000 A-scans per second. With a substantial improvement in scan speed, the anterior chamber angles can be imaged 360 degrees in 128 cross sections (each with 512 A-scans) in about 2.4 seconds. We summarize the clinical applications of anterior segment SS-OCT in Glaucoma.\n\nLiterature search: We searched PubMed and included Medline using the phrases anterior segment optical coherence tomography in ophthalmology, swept-source OCT, use of AS-OCT in glaucoma, use of swept-source AS-OCT in glaucoma, quantitative assessment of angle, filtering bleb in AS-OCT, comparison of AS-OCT with gonioscopy and comparison of AS-OCT with UBM. Search was made for articles dating 1990 to August 2015."
    }
]