        "id": "osp-12488",
        "type": "article-journal",
        "title": "Central corneal thickness measurement using ultrasonic pachymeter, optical coherence tomography, and TMS-5 topographer",
        "author": [
            {
                "family": "Binnawi",
                "given": "Kamal Hashim"
            },
            {
                "family": "Elzubeir",
                "given": "Hanaa"
            },
            {
                "family": "Osman",
                "given": "Eman"
            },
            {
                "family": "Abdu",
                "given": "Malaz"
            },
            {
                "family": "Abdu",
                "given": "Mustafa"
            }
        ],
        "URL": "https://omanscience.com/en/articles/central-corneal-thickness-measurement-using-ultrasonic-pachymeter-optical-coherence-tomography-and-tms-5-topographer",
        "language": "en",
        "issued": {
            "date-parts": [
                [
                    2019
                ]
            ]
        },
        "container-title": "Oman Journal of Ophthalmology",
        "volume": "12",
        "issue": "1",
        "page": "15-19",
        "DOI": "10.4103/ojo.ojo_96_2018",
        "publisher": "Medknow Publications",
        "ISSN": "0974-620X",
        "abstract": "Aim: This study aimed to compare the central corneal thickness (CCT) measurements using Optical Coherence Tomography (OCT) and TMS-5 topographer with that taken with the gold standard digital Ultrasonic pachymeter (USP).\n\nMaterials and methods: A total of 61 subjects (122 eyes) were prospectively and consecutively studied in a period from June 2016 to June 2017 at Sudan Eye Centre (SEC), Khartoum, Sudan. Besides the visual and refractive data, measurements of CCT were taken using OCT, TMS-5 and USP. Data analyzed using SPSS software for windows (IBM SPSS 20, IBM Corp., Armonk, NY).\n\nResults: A statistically significant differences in mean CCT was detected between the three instruments (P < 0.001). USP was found to measure the CCT 29μm thicker than OCT and 22μm thicker than TMS-5 topographer. A significant difference was also found between OCT and TMS-5. OCT found to give the lower values of CCT compared to both USP and TMS-5 topographer. Further analysis showed that the three procedures were significantly and strongly correlated to each other (USP vs OCT, r = 0.77), (USP vs TMS-5, r = 0.78) and (OCT vs TMS-5, r = 0.80).\n\nConclusion: Mean central corneal thicknesses (CCT) were comparable among OCT, TMS-5 topographer and the gold standard USP. However, there is a reproducible systematic difference between CCT measurements taken with the three devices. It is important to note in clinical practice, that measurements acquired by these three modalities are not directly interchangeable."
    }
]